New England Journal of Medicine November 08, 2026

Left Bundle-Branch Pacing versus Right Ventricular Pacing for Atrioventricular Block

Zhiyong Qian, Lingyun Jiang, Xiaofeng Hou, Xiaolin Xue, Min Shen, et al. (OptimPacing Investigators)

Bottom Line

In patients with atrioventricular block, left bundle-branch pacing significantly reduced the composite risk of death, heart failure hospitalization, or pacing-induced cardiomyopathy compared to traditional right ventricular pacing.

Key Findings

1. At four years, the primary composite outcome (all-cause death, heart failure hospitalization, or pacing-induced cardiomyopathy) occurred in 8.5% of the left bundle-branch pacing (LBBP) group compared to 19.2% of the right ventricular pacing (RVP) group (HR 0.41; 95% CI 0.23 to 0.75).
2. The clinical benefit was entirely driven by the prevention of pacing-induced cardiomyopathy, which occurred in 0% of the patients assigned to LBBP versus 11.7% in the RVP arm.
3. Rates of all-cause death (7.4% vs. 7.7%) and heart failure hospitalization (1.5% vs. 2.9%) were statically similar between the LBBP and RVP groups.
4. LBBP was successfully implanted in 96.8% of patients, with confirmed left bundle branch capture in 87.6%, and both groups experienced a high ventricular pacing burden (>90%).

Study Design

Design
RCT
Open-Label
Sample
702
Patients
Duration
4 yr
Median
Setting
Multicenter, International
Population Adult patients with atrioventricular block and an indication for permanent pacing, predominantly with normal baseline left ventricular ejection fraction.
Intervention Left bundle-branch pacing (LBBP).
Comparator Standard right ventricular pacing (RVP).
Outcome Composite of all-cause death, heart failure hospitalization, or pacing-induced cardiomyopathy (defined as a ≥10% drop in LVEF resulting in an LVEF ≤50% without alternative causes).

Study Limitations

• The trial was stopped early for efficacy, which inherently carries the risk of overestimating the true magnitude of the treatment effect.
• The study utilized an open-label design; while the primary outcome includes objective criteria (like death and ejection fraction changes), lack of blinding can introduce bias into clinical decision-making regarding hospitalizations.
• The enrolled population predominantly consisted of patients with normal baseline left ventricular ejection fraction, meaning these results cannot necessarily be generalized to patients with pre-existing heart failure or significantly reduced LVEF.
• The procedures utilized a single type of pacing lead, which may restrict the broad applicability of the technical and safety findings to other commercially available device systems.

Clinical Significance

The OptimPacing trial provides landmark randomized evidence that conduction system pacing—specifically left bundle-branch pacing—prevents the electrical and mechanical dyssynchrony typically caused by standard right ventricular pacing. By demonstrating a near elimination of pacing-induced cardiomyopathy (0% vs 11.7%) in a population requiring a heavy pacing burden, these data strongly support a paradigm shift toward making LBBP the default, standard-of-care pacing strategy for patients with atrioventricular block and normal baseline cardiac function.

Historical Context

For decades, the standard treatment for atrioventricular block has been right ventricular (RV) pacing. While life-saving and highly reliable, pacing the right ventricle creates an artificial left bundle branch block pattern. Over time, this electrical dyssynchrony can lead to mechanical dyssynchrony, left ventricular adverse remodeling, and pacing-induced cardiomyopathy, particularly in patients with a high pacing burden. His-bundle pacing emerged as a physiological alternative but suffered from high capture thresholds, sensing issues, and technically challenging lead placements. Left bundle-branch pacing (LBBP) was recently pioneered to bypass the site of block while providing a wider target and better electrical parameters. OptimPacing serves as a definitive trial validating the long-term clinical superiority of LBBP over RV pacing.

Guided Discussion

High-yield insights from every perspective

Med Student
Medical Student

How does traditional right ventricular pacing lead to pacing-induced cardiomyopathy, and anatomically, why does left bundle-branch pacing (LBBP) mitigate this risk?

Key Response

Right ventricular pacing creates an artificial left bundle branch block pattern, causing mechanical dyssynchrony. The right ventricle contracts before the left, leading to adverse remodeling, cellular-level alterations in calcium handling, and eventually a decreased ejection fraction (pacing-induced cardiomyopathy). LBBP directly stimulates the left conduction system deep in the interventricular septum, resulting in rapid, synchronous left ventricular activation that preserves physiological ventricular mechanics.

Resident
Resident

A 65-year-old patient with complete heart block requires a pacemaker. Based on recent data comparing LBBP to RVP, which patient factors would most strongly favor attempting LBBP as the initial strategy rather than standard right ventricular pacing?

Key Response

Patients with an expected high ventricular pacing burden (e.g., >20%), baseline mild-to-moderate left ventricular dysfunction (EF 36-50%), or pre-existing heart failure are at the highest risk for pacing-induced cardiomyopathy with standard RVP. In these populations, LBBP is strongly favored to prevent clinical deterioration, heart failure hospitalization, and adverse remodeling.

Fellow
Fellow

While LBBP shows superiority over RVP in preventing pacing-induced cardiomyopathy, what are the specific procedural challenges, anatomical pitfalls, and potential unique long-term complications of deep septal lead deployment compared to traditional RV apical leads?

Key Response

LBBP requires driving the lead deep into the interventricular septum to capture the left bundle. Procedural challenges include the risk of septal perforation into the left ventricle, damage to septal coronary arteries, and a steeper learning curve for delivery sheath manipulation. Long-term concerns include questions about lead extractability, the potential for late septal mechanical damage, and capture threshold rises, which demand nuanced patient selection and meticulous follow-up.

Attending
Attending

Given the significant reduction in the composite risk of death, HF hospitalization, or pacing-induced cardiomyopathy with LBBP, should we abandon traditional RVP entirely for AV block, or are there still distinct clinical scenarios where RVP remains the standard of care?

Key Response

While LBBP is superior for patients needing a high ventricular pacing burden, RVP remains appropriate and often preferred for patients with expected infrequent pacing (e.g., intermittent sinus node dysfunction without AV block), those with extreme frailty or limited life expectancy where procedural time and risk must be minimized, or in cases of challenging right-sided anatomy where deep septal penetration is unfeasible or carries unacceptable perforation risk.

Scholarly Review

Critical appraisal through the lens of expert reviewers and guideline development

PhD
PhD

The trial utilizes a composite primary endpoint of death, heart failure hospitalization, or pacing-induced cardiomyopathy. How might the inclusion of a surrogate echocardiographic outcome alongside hard clinical outcomes bias the interpretation of the treatment effect, and how should competing risks be modeled in this statistical context?

Key Response

Combining a surrogate imaging endpoint (PICM) with mortality and HF hospitalization can inflate the apparent treatment effect if the event rate is primarily driven by the surrogate rather than hard clinical outcomes. Furthermore, mortality acts as a competing risk for developing PICM; a rigorous statistical approach must employ Fine-Gray subdistribution hazard models or similar competing risk frameworks to ensure the reduction in PICM is not merely an artifact of differential mortality or unequal follow-up duration between the study arms.

Journal Editor
Journal Editor

In a randomized trial of LBBP versus RVP, blinding the treating physicians and patients is virtually impossible due to distinct ECG morphologies. What specific blinded adjudication processes and missing data handling strategies must be detailed in the manuscript to convince a peer reviewer that the primary outcome results are free from ascertainment bias?

Key Response

Because the pacing modality is obvious on an ECG (narrow/pseudo-RBBB vs. wide QRS LBBB pattern), unblinded clinicians might have a lower threshold to admit RVP patients for heart failure or alter medical therapy. A robust trial must use a blinded Clinical Events Committee to adjudicate HF hospitalizations and a blinded core lab for serial echocardiographic evaluation of PICM. Additionally, the handling of crossover (e.g., failed LBBP converted to RVP) must be strictly analyzed via intention-to-treat to prevent bias favoring the intervention arm.

Guideline Committee
Guideline Committee

Current ACC/AHA/HRS and ESC guidelines give conduction system pacing a Class IIa/IIb recommendation for AV block patients with an anticipated high pacing burden. Does the evidence from this trial justify elevating LBBP to a Class I recommendation for all patients with AV block, and how does this affect the strength of recommendation for baseline normal versus reduced ejection fraction subgroups?

Key Response

If this trial demonstrates a robust, generalizable reduction in hard clinical outcomes across all EF strata, it could compel guidelines to upgrade LBBP (or conduction system pacing broadly) to a Class I (Level of Evidence: B-R or A) recommendation for patients with expected >20% pacing. However, if the benefit is predominantly driven by patients with borderline or reduced baseline EF (36-50%), the Class I recommendation might remain restricted to that specific subgroup, leaving LBBP as a Class IIa alternative to RVP for patients with strictly normal baseline left ventricular function.

Clinical Landscape

Noteworthy Related Trials

2002

DAVID Trial

n = 506 · JAMA

Tested

Dual-chamber pacing (DDDR) at 70 bpm

Population

Patients with standard indications for an ICD and no indication for antibradycardia pacing

Comparator

Ventricular backup pacing (VVI) at 40 bpm

Endpoint

Composite of time to death or first hospitalization for congestive heart failure

Key result: Dual-chamber pacing that forced unnecessary right ventricular pacing resulted in increased rates of heart failure hospitalization and mortality.
2013

BLOCK HF Trial

n = 718 · NEJM

Tested

Biventricular pacing

Population

Patients with AV block and left ventricular systolic dysfunction

Comparator

Right ventricular pacing

Endpoint

Composite of death, heart failure urgent care visit, or adverse LV remodeling

Key result: Biventricular pacing significantly reduced the incidence of the primary composite endpoint compared with right ventricular pacing.
2019

His-SYNC Trial

n = 41 · JACC

Tested

His-bundle pacing

Population

Patients with heart failure meeting indications for cardiac resynchronization therapy

Comparator

Biventricular pacing

Endpoint

Improvement in QRS duration and left ventricular ejection fraction at 6 months

Key result: While not meeting its primary endpoint due to crossover, His-bundle pacing achieved significant QRS narrowing and demonstrated the feasibility of conduction system pacing.

Tailored to your role

Want this tailored to you?

Add your specialty or training stage to get role-specific takeaways and more questions.

Personalize this analysis
↑